Accuracy
Up to 0.030 mm(1)
(0.0012 in)(1)
Volumetric accuracy
(based on part size)
(based on part size)
0.020 mm + 0.060 mm/m(2)
(0.0008 in + 0.0007 in/ft)(2)
Volumetric accuracy with MaxSHOT Next™|Elite
0.030 mm + 0.015 mm/m(3)
(0.0012 in + 0.00018 in/ft)(3)
Measurement capabilities (at a working distance of 0.35 m (1.2ft) )
1.00 mm
(0.0393 in)
1.50 mm
(0.0591 in)
0.030 mm
(0.0012 in)
0.75 mm
(0.0295 in)
Measurement resolution
0.025 mm
(0.0010 in)
Mesh resolution
0.100 mm
(0.0039 in)
Measurement rate
1,200,000 measurements/s
Light source
23 blue laser lines(4)
Scanner Controls
Touchscreen display
Working Distance
250 to 450 mm
(9.8 to 17.7in)
Depth of field
200 mm
(7.9 in)
Part size range (recommended)
0.05-4 m
(0.15-13.1 ft)
Output formats
.dae, .fbx,.iges, .ma, .obj, .ply, .step, .stl, .txt, .wrl, .x3d, .x3dz, .zpr, .3mf
Reverse Engineering Software
Scan-to-CAD Pro (included)
Compatible software
3D Systems (Geomagic® Solutions), InnovMetric Software (PolyWorks), Metrologic Group (Metrolog X4), New River Kinematics (Spatial Analyzer), Verisurf, Dassault Systèmes (CATIA V5, SOLIDWORKS), PTC (Creo), Siemens (NX, Solid Edge), Autodesk (Inventor, PowerINSPECT)(5)
Weight
920 g
(2.0 lb)
Dimensions
(LxWxH)79 x 150 x 304 mm
(3.2 x 5.9 x 12 in)
Connection standard
1 X USB 3.0
Operating temperature range
5-40 °C
(41-104 °F)
Operating humidity range (non-condensing)
10-90%
Certifications
EC Compliance (Electromagnetic Compatibility Directive, Low Voltage Directive), compatible with rechargeable batteries (when applicable), IP50, WEEE
Patents
CA 2,600,926, US 7,912,673, CA 2,656,163, EP (FR, UK, DE) 1,877,726, AU 2006222458, US 8,032,327, JP 4,871,352, US 8,140,295, EP (FR, UK, DE) 2,278,271, EP (FR, UK, DE) 2,230,482, IN 266,573, EP (FR, UK, DE) 3,102,908, US 10,271,039, JP 6,596,433, CA 2,938,104, KR 10-2424135, EM 009203334-0001, EM 009203334-0002, EM 009203334-0003, EM 009203334-0004, EM 009203334-0005, EM 009203334-0006, CN 220,206,623 U, CN 308805542 S, CN 221,445,081 U
(1) Typical value for diameter measurement on a calibrated sphere artefact.
(2) Value for spheres spacing measurement on a calibrated length artefact. Results are obtained using integrated photogrammetry with volumetric accuracy optimization.
(3) The volumetric accuracy of the system when using a MaxSHOT 3D cannot be superior to the default accuracy for a given model.
(4) Laser class: 2M (eye safe).
(5) Also compatible with all major metrology, CAD, and computer graphic software through mesh and point cloud import.
전세계 고객 지원, 수리 및 검교정 센터
Creaform의 계측 센터는 전 세계에 위치해 있으며 다양한 언어로 다음 서비스*를 제공합니다.
소프트웨어 및 하드웨어 기술 지원 서비스
3D 스캐너 기본 및 고급 수리
장비 유지보수, 튜닝 및 보정
대체 장비 서비스
3D 스캐너 구성품 교체
부품 재판매
보증 갱신
* 서비스는 각 계측 센터마다 다를 수 있습니다.
타협하지 않는 제조 3D 스캐닝 프로세스
Creaform은 국제적으로 인정되는 표준인 ISO 9001에 따라 최고 수준의 품질 관리 시스템으로 HandySCAN 3D 스캐너를 설계, 제조 및 검교정합니다.
저희는 처음부터 마지막 단계까지, 프로세스를 책임지고 있다는 것에 자부심을 가지고 있습니다. 각 스캐너는 정확도 인증서와 테스트 결과 문서와 함께 배송 됩니다.
세계적인 수준의 고품질 및 3D 정밀 표준
Creaform에서는 제품 및 서비스 품질을 최우선으로 고려하고 있습니다.휴대용 3D 측정 분야를 개척한 당사는 고객의 요구 그 이상을 충족하는 혁신적인 솔루션을 개발하기 위해 최선을 다하고 있습니다. 저희는 지속적으로 프로세스를 개선하고 새로운 업계 표준을 설정하며 고객 만족 보장에 투자를 하고 있습니다.
저희는 처음부터 마지막 단계까지, 프로세스를 책임지고 있다는 것에 자부심을 가지고 있습니다. 각 스캐너는 정확도 인증서와 테스트 결과 문서와 함께 배송 됩니다.
세계적인 수준의 고품질 및 3D 정밀 표준
Creaform에서는 제품 및 서비스 품질을 최우선으로 고려하고 있습니다.휴대용 3D 측정 분야를 개척한 당사는 고객의 요구 그 이상을 충족하는 혁신적인 솔루션을 개발하기 위해 최선을 다하고 있습니다. 저희는 지속적으로 프로세스를 개선하고 새로운 업계 표준을 설정하며 고객 만족 보장에 투자를 하고 있습니다.
HandySCAN 3D | PRO
시리즈 관심이 있으십니까?
Creaform 기술 어드바이저에게 문의하세요.